Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

MYR59.00
+ MYR41.99 送货

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • 品牌: Unbranded

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • 品牌: Unbranded
建议零售价: MYR119.00
价格: MYR59.00
您节省了: MYR60.00 (50%)
由……售出:
MYR59.00
+ MYR41.99 送货

有货

我们接受以下付款方式

描述

Item Type:Relay Module Product Model: YF-11 Input Voltage:DC7~24V Output Power: Can Control DC Power Load within 10A Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc. P-21: Give the signal, after a delay of A second, the output starts P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops. P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second. P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal) P-28: After power on, after a delay of A second, the output starts until the power is off P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped. P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within A+B time P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time P-42: The signal disappears, after a delay of time A, the output starts; working time B ends P-43: The signal disappears. After the time A exceeds, the output starts; the working time B ends P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop. P-45: No action when energized, after signal is given; output starts A time, stops B time; cycle C times and automatically stops; Give signal again, execute again P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off P-47: After giving the signal more than A times, the output starts and stops for B seconds P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds 3. Description of button setting: Power on display "" means entering standby state; Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit) Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) Press K1 for the fourth time, the display "" means entering the standby state Press K4 in standby mode to permanently turn off/on the display and switch to low power consumption mode 4. The decimal point time unit description: X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds XXX has no decimal point, timing range: 1 second to 999 seconds XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes
  • Fruugo ID: 321526152-713414810
  • EAN: 1121763908682

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

安全警告: Do not let your children touch this product alone to avoid swallowing or other injuries.

配送 & 退货

在 3 天内发货

  • STANDARD: MYR41.99 - 之间的交付 周五 31 十月 2025–周五 07 十一月 2025

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611