描述
The functions of the product are mainly classified into two categories: temperature function and humidity function;
The temperature function is as follows:
1. Automatic working mode identification:
The system automatically recognizes the working mode according to the start temperature/stop temperature;
Start temperature > stop temperature, cooling mode 'C'; starting temperature < stop temperature, heating mode 'H';
2. Cooling mode:
When the detected temperature starting temperature, the relay is activated, the red light is on, and the refrigeration equipment starts to work;
When the temperature of detection the stop temperature, the relay is off, the red light is off, and the refrigeration equipment stops working;
3. Heating mode:
When the detected temperature the starting temperature, the relay is turned on, the red light is on, and the heating equipment starts to work;
When the temperature detection stop temperature, the relay is closed, the red light is off, and the heating equipment stops working
4. OFE(-10.0 ~ 10.0) temperature correction function:
The system works for a long time and deviations may occur. Through this function correction, the actual temperature = measured temperature + value calibration;
How to set start/stop temperature:
1. On the running interface, press and hold "TM+" key for more than 3 seconds to enter the start temperature setting interface. The test can modify the parameters via the TM+ TM- key. When finished changing settings, wait 6 seconds to automatically exit and save;
2. In the running interface, press and hold "TM-" key for more than 3 seconds to enter the shutdown temperature setting interface. The test can modify the parameters via the TM+ TM- key. When finished changing settings, wait for 6 seconds to automatically exit and save;
Humidity functions are as follows:
1. Automatic working mode identification:
The system automatically recognizes the working mode according to the start humidity/stop temperature;
Start humidity > stop humidity, dehumidification mode d; start humidity < stop humidity, humidification mode E;
2. Dehumidification mode:
When the detected humidity start humidity, the relay is activated, the green light is on, and the dehumidification equipment starts to work;
When the humidity detectedstop the humidity, the relay is off, the green light is off, and the dehumidification equipment stops working;
3. Humidification mode:
When the detected humidity the starting humidity, the relay is activated, the green light is on, and the humidification device begins to work;
When the humidity detected stops the humidity, the relay is turned off, the green light is off, and the humidification device stops working
4. RH humidity correction function (-10.0 ~ 10.0 ):
The system works for a long time and there may be deviations. With this function correction, the actual humidity = measured humidity + calibration value;
How to set start/stop humidity:
1. On the running interface, press and hold the "RH+" button for more than 3 seconds to enter the start humidity setting interface. The test can change the parameters by pressing the RH + RH- button. When the settings change is complete, wait 6 seconds to automatically exit and save;
2. On the running interface, press and hold "RH-" button for more than 3 seconds to enter the stop humidity setting interface. The test can change the parameters by pressing the RH + RH- button. When finished changing settings, wait 6 seconds to automatically exit and save
-
Fruugo ID: