描述
16 Logical Channels+)+2 Analog Channels + External Trigger Channel Hantek 60MHz
MSO5062D Mixed Signal Digital Oscilloscope
Specifications:
Model
MSO5202D
MSO5102D
MSO5062D
Acquisition
Sample Rate
Real-Time Sample: 1GS/s
Acquisition Modes
Normal
Normal data only
Peak Detect
High-frequency and randon glith capture
Average
Waveform Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling
AC, DC, GND
Inputs Impendance
1MΩ±2% &
8214;20pF±3pF
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factor
1X, 10X, 100X, 1000X
Maximum Input Voltage
CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range
500MS/s--1GS/s
Waveform Interpolation
(sin x)/x
Record Length
1M
SEC/DIV Range
2ns/div to 40s/div,
8ns/div to 40s/div
Sample Rate and
Delay Time Accuracy
±50ppm&
65288;at over any ≥1ms time interval)
Position Range
2ns/div to 8ns/div;
(-8div x s/div) to 20ms;
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s;
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution
8-bit resolution, all channel sampled simultaneously
Position Range
2mV/div to 10V/div
Bandwidth
200MHz
100MHz
60MHz
Rise Time at BNC( typical)
1.8ns
3.
-
Fruugo ID:
229850706-490493768
-
EAN:
884132549855
产品安全信息
请参阅下面列出的特定于该产品的产品安全信息
以下信息由销售该产品的独立第三方零售商提供。
产品安全标签
安全警告:
Please note that the product is safe under normal use conditions. However, improper use may lead to hazards such as damage, injury or other safety risks. Please read and follow the instructions carefully.This product complies with EU safety standards. However, for your safety, if any abnormality (such as strange smell, overheating, loose parts, etc.) is found during use, please stop using it immediately.In accordance with the EU General Product Safety Regulation, we remind you that this product is only suitable for [specific applicable people / scenarios]. Use in non - specified people / scenarios may bring potential safety hazards.