描述
Item Type: Switching Power_x000D_
Product Material: Aluminum alloy_x000D_
Product Model: NDR-75-24_x000D_
DC Output Range: 24V, 0-3.2A_x000D_
Output Voltage Accuracy: 1%_x000D_
Ripple and Noise: 150mV_x000D_
Efficiency: 88%_x000D_
Input Voltage: 100-240VAC_x000D_
Overload Protection: Constant current limit when the rated output power reaches 105%130%, and it will automatically recover after the load is normal_x000D_
Over-Voltage Protection: Output Voltage 12V: 1417V, 24V: 2933V, 48V: 5665V when shut down, restart and restore_x000D_
Overheating Protection: Overheating shutdown, automatic recovery after the temperature drops_x000D_
Start-up and Hold Time: 1200ms, 60ms, 60ms/115VAC, 2000ms, 60ms, 12ms at full load of 230VAC_x000D_
Insulation Characteristics: Between Input And Output: 3KVac, Between Input and Shell: 2KVac, Between Output and Shell: 0.5KVac, 1 minute_x000D_
Working Temperature: -20+70(reference for output derating curve)_x000D_
Vibration Resistance: 10500Hz, 2G 10 minutes/cycle, XYZ axis each 60 minutes; installation conforms to IEC60068-2-6_x000D_
Safety Certification: Passed UL508, TUV EN60950-1 certification_x000D_
Electromagnetic Compatibility Standards: Emission: EN55022 (CISPR22), EN61204-3, Class B, Harmonics: EN61000-3-2, -3_x000D_
Electromagnetic Compatibility Standards: Anti-interference EN61000-4-2,3,4,5,6,8,11, ENV55024, EN61000-6-2 (EN50082-2), EN61204-3, Class A heavy industry standard_x000D_
Mean Time Between Failures: 486,200 hours, MIL-HDBK-217F (25)_x000D_
Wiring Mode: Input End: 3 Points. Output End: 4 points screw DIN terminal_x000D_
Chassis Number: 221B_x000D_
Product Size: Approx. 102 x 125.2 x 32mm / 4 x 4.9 x 1.3in(WxHxD)_x000D_
How to Use: _x000D_
1. The AC voltage specifications that the rail power supply can use are 110VAC, 220VAC and 380VAC. Therefore, before turning on the power supply, carefully check whether the connected voltage and the input voltage of the power supply are correct and consistent._x000D_
2. Do not load before powering on for the first time. First check whether the output voltage of the power supply is the same as the power supply of the connected equipment to avoid damage to the connected equipment._x000D_
3. Before using the power supply, please confirm whether the ground wire is properly connected, and mark the position of the specific power ground wire in the figure._x000D_
4. The power supply must be placed in a well-ventilated place with fast heat dissipation before and after use._x000D_
5. The determination of the output current of the rail power supply is closely related to the environment. It is determined based on the rated standard current of the rail power supply provided by the equipment or the average current value measured by a multimeter. And in the case of high ambient temperature, poor air flow conditions, and excessive inductive load, 20-30% more current margin must be prepared._x000D_
6. The input power of the rail power supply is generally determined by the input power of the rail power supply, which determines the rated power of the equipment supplied. However, in the case of not knowing the specific rated power of the equipment supplied, there are also certain modifications, and the power can be obtained based on the product of the rated current and voltage of the equipment supplied, that is, current x voltage. It should be noted that when the user selects the power supply, it should be greater than 15-30% of the actual power and peak power.
-
Fruugo ID:
310796007-694782403
-
EAN:
6270765324510