描述
1、Current Sensor Module: Can easily detect the DC current and control the on and off of relay according to the set limit current. 2、Wide Detection Range: The voltage detection range is 7‑30V, and the current detection range is 0‑30A, meeting various needs. 3、Accurate Measurement: With a high measurement accuracy up to 0.1A, the sensor module has error calibration function as well. 4、Circuit Protection: Used to limit the current in the circuit and protect electrical equipment from damage caused by the current. 5、Convenient Operation: The digital display can be turned off for a long time to reduce power consumption, useful and convenient.
Item Type: Current Detection Module
Product Model: YYI-4
Voltage Detection Range: DC7-30V
Current Detection Range: 0~30A
Detection Accuracy: 0.1A (100mA).
Standby Current: About 20mA.
Relay Output: Can control the on and off of DC lines within 30A.
Function: Detect whether the current is too large or too small, control the relay switch to control the line on and off, or give a signal.
How to Use:
No. 1 Operation Instructions:
1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected;
2. P-12: When the measured current is greater than I1, the relay is closed; it always stays closed until the circuit board is powered off;
3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected;
4. P-22: When the measured current is greater than I2, the relay is closed; it always stays closed until the circuit board is powered off;
5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected;
6. P-32: When the measured current is less than I1, the relay is closed; it always stays closed until the circuit board is powered off;
7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected;
8. P-42: When the measured current is between I1 and I2, the relay is closed; it always stays closed until the circuit board is powered off;
9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected;
10.P-52: When the measured current is less than I1 or greater than I2, the relay will be closed; it will always be closed until the circuit board is powered off.
No. 2 Setting Instructions:
1. Power on to display the measured current(if the measured current terminal is suspended, the number of digital display is normal);
2. The first time K1 is pressed, it takes more than 1 second to effective prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function
3. Press K1 for the second time, the screen flashes 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus;
4. Press K1 for the third time, the screen flashes 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus
5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state;
6. In standby mode, long press K2 or K3 to fine tune the measured current error.
1 x Current Detection Module
-
Fruugo ID:
388423454-833297711
-
EAN:
680141656139