DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

MYR34.95
免费送货

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

  • 品牌: Unbranded

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

  • 品牌: Unbranded
价格: MYR34.95
由……售出:
MYR34.95
免费送货

14天退货政策

目前缺货

我们不知道该产品是否补货以及什么时候会有货。

付款方式:

描述

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

Features: To achieve fast high frequency turn-on and off circuit, an unlimited number of switching times. No noise was made during turning on/off, no spark, and no electromagnetic interference. Compared to normal electromagnetic relay modules, it has a longer service life. Dual-MOS in parallel active output, lower inner resistance, larger current, strong power; at room temperature, operating current is up to 15A, power up to 400W, that can be used for most equipment. Wide voltage input from 5V to 36V, normally used for controlling DC motors, lights, LED strips, micro-pumps, solenoid valves, etc., very convenient. It has an emergency stop function ("STOP" button) and reverse input protection. Automatically enter sleep mode and shut off display if no operation in 5 minutes, and will be wake up by pressing any button. You can set different OP, CL, LOP parameters, which are independent of each other, and are saved separately; All parameter settings will be saved automatically if there is a power failure. Specifications: Voltage: DC 5V~36V. Trigger Signal Source: High voltage level trigger (3.0V~24V), signal ground and system ground are not on common ground to improve the system's anti-jamming capability (you can also connect them on common ground). Output Capacity: DC 5V~36V, at room temperature, continuous current is 15A, power 400W. With enhanced heat dissipation, the current can be up to 30A. Quiescent Current: 20mA Operating Current: 50mA Working Temperature: -40~85 Clocking (Time Delay) Range: 0.1seconds to 999minutes Size: 60*34*12mm / 2.36*1.33*0.47" Instruction: Operating Mode: P1: trigger signal, the relay is on "OP" time, and then disconnect; in the "OP" time, as follows: P1.1: signal is triggered again, invalid P1.2: signal is triggered again, the clocking is reset P1.3: Signal is trigger again reset, relay off, and stop the clocking; P-2: trigger signal, the relay off "CL" of time, the relay on "OP" time, and then disconnect relay after clocking; P3.1: trigger signal, the relay is turned on after the "OP" time, the relay off "CL" time, then the operation cycles; if trigger signal again during the cycle, the relay off, stop clocking; the number of cycles times ( "LOP ") can be set. P3.2: without triggering signal after power on, the relay is on "OP" time, the relay off "CL" time, then the operation cycles; the number of cycles times ( "LOP ") can be set. P-4: signal holding function. If there is trigger signal, clocking is reset, the relay remains on; when the signal disappears, after clocking "OP" time, the relay is off; if another signal is triggered during clocking, clocking will be reset. How to Set Clocking Range: After setting the parameter value at mode selection, press "STOP" button to set the clocking range; XXX. The last decimal point lights up, range: 1 second to 999 seconds. XX. X The second last decimal point lights up, range: 0.1 seconds to 99.9 seconds X. X. X. all 3 decimal points light up, range: 1 minute to 999 minutes. For example, if you want to set "OP" as 3.2 seconds, light up the second last decimal point, and set digit display as 03.2 Parameter Description: "OP" - on time, "CL" - off time, "LOP" - number of cycle times (1-999 times, "---" represents infinite loop). These parameters are independent of each other, but are shared by each mode. For example, in P1.1 mode, set the on-time "OP" is 5 seconds, if you switch to P1.2 mode, its "OP" will also be 5 seconds. In the main interface (display 000), press "SET" button will display "OP" ( "CL", "LOP") and the corresponding time XXX; If the mode (such as the mode P1.1, P1.2, P1.3) only has "OP" time, press the "SET" key to display only the "OP" and the corresponding time; Some models (such as the mode P3.1, P3.2) have parameters "OP", "CL", "LOP", press "SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times; After setting mode, in the main interface press "SET" key to see information about the parameters of the current mode, very convenient. How to Set Parameters: 1. First, read the instructions to determine the required operating mode.
  • Fruugo ID: 163140558-346827634
  • EAN: 6493555524772

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: Please use and store the product correctly according to the instructions

配送 & 退货

在 -1 天内发货

  • STANDARD: 免费 - 之间的交付 周二 06 一月 2026–周四 15 一月 2026 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • Shenzhen Yangxi Trading Co., Ltd.
  • Shenzhen Yangxi Trading Co., Ltd.
  • No. 203, No. 3, Lane 3, Houshan West, Xiaxue Village, Xinxue Community, Bantian Street, Longgang
  • Shenzhen
  • CN
  • 518129
  • wqvkk3@163.com

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM. 1, PLANTA 1, DERECHA, OFICINA 3, Fuenlabrada, Madrid, 28947 Spain
  • Frankfurt am Main
  • ES
  • 28947
  • successservice2@hotmail.com
  • 34910602659