DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

MYR40.95
免费送货

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

  • 品牌: Unbranded

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

  • 品牌: Unbranded
建议零售价: MYR54.00
价格: MYR40.95
您节省了: MYR13.05 (24%)
由……售出:
MYR40.95
免费送货

有货

我们接受以下付款方式

描述

Features:To achieve fast high frequency turn-on andoff circuit, an unlimited number of switching times.No noise was made during turning on/off, nospark, and no electromagnetic interference.Compared to normal electromagnetic relaymodules, it has a longer service life.Dual-MOS in parallel active output, lower innerresistance, larger current, strong power; at room temperature, operatingcurrent is up to 15A, power up to 400W, that can be used for most equipment.Wide voltage input from 5V to 36V, normallyused for controlling DC motors, lights, LED strips, micro-pumps, solenoidvalves, etc., very convenient.It has an emergency stop function ("STOP" button)and reverse input protection.Automatically enter sleep mode and shut offdisplay if no operation in 5 minutes, and will be wake up by pressing anybutton.You can set different OP, CL, LOPparameters, which are independent of each other, and are saved separately;All parameter settings will be savedautomatically if there is a power failure. Specifications:Voltage: DC 5V~36V.Trigger Signal Source: High voltage leveltrigger (3.0V~24V), signal ground and system ground are not on common ground toimprove the system's anti-jamming capability (you can also connect them oncommon ground).Output Capacity: DC 5V~36V, at roomtemperature, continuous current is 15A, power 400W. With enhanced heatdissipation, the current can be up to 30A.Quiescent Current: 20mAOperating Current:50mAWorking Temperature: -40~85Clocking (Time Delay) Range: 0.1seconds to999minutesSize: 60*34*12mm / 2.36*1.33*0.47"Instruction: Operating Mode:P1: trigger signal, the relay is on"OP" time, and then disconnect; in the "OP" time, asfollows:P1.1: signal is triggered again, invalidP1.2: signal is triggered again, the clockingis resetP1.3: Signal is trigger again reset, relayoff, and stop the clocking;P-2: trigger signal, the relay off"CL" of time, the relay on "OP" time, and then disconnectrelay after clocking;P3.1: trigger signal, the relay is turnedon after the "OP" time, the relay off "CL" time, then theoperation cycles; if trigger signal again during the cycle, the relay off, stopclocking; the number of cycles times ( "LOP ") can be set.P3.2: without triggering signal after poweron, the relay is on "OP" time, the relay off "CL" time, thenthe operation cycles; the number of cycles times ( "LOP ") can beset.P-4: signal holding function. If there is triggersignal, clocking is reset, the relay remains on; when the signal disappears,after clocking "OP" time, the relay is off; if another signal istriggered during clocking, clocking will be reset.How to Set Clocking Range:After setting the parameter value at modeselection, press "STOP" button to set the clocking range;XXX. The last decimal point lights up,range: 1 second to 999 seconds.XX. X The second last decimal point lightsup, range: 0.1 seconds to 99.9 secondsX. X. X. all 3 decimal points light up,range: 1 minute to 999 minutes.For example, if you want to set"OP" as 3.2 seconds, light up the second last decimal point, and setdigit display as 03.2Parameter Description: "OP" - ontime, "CL" - off time, "LOP" - number of cycle times (1-999times, "---" represents infinite loop).These parameters are independent of each other,but are shared by each mode. For example, in P1.1 mode, set the on-time"OP" is 5 seconds, if you switch to P1.2 mode, its "OP"will also be 5 seconds.In the main interface (display 000), press"SET" button will display "OP" ( "CL","LOP") and the corresponding time XXX;If the mode (such as the mode P1.1, P1.2,P1.3) only has "OP" time, press the "SET" key to displayonly the "OP" and the corresponding time;Some models (such as the mode P3.1, P3.2)have parameters "OP", "CL", "LOP", press"SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times;After setting mode, in the main interface press"SET" key to see information about the parameters of the currentmode, very convenient.How to Set Parameters:1. First, read the instructions todetermine the required operating mode.2. The module is powered up, the display atthe current work mode (P1.1 default mode), then enter the main interface; pressand hold "SET" button for 2 seconds to enter mode selectioninterface; then press "UP", "DOWN" button to select themode (P1.1 ~ P-4).3. Select the mode (such as P3.2), thenpress the "SET" button, the parameter to be set flashes ("OP" on-time, "CL" off time, "LOP" cycles ("---" represents infinite loop)), press(or press and hold)"UP", "DOWN" button to adjust the parameter value; thenpress the "STOP" key to set the decimal point position to select the clockingrange (0.1 seconds to 999 minutes); press the "SET" button to set thenext parameters of the current mode, method is same as above.4. After the parameters are set, press andhold "SET" button for 2 seconds, then the current mode will flashonce, and then return to the main interface, which means the parameters are successfullyset.The main inte
  • Fruugo ID: 419699423-884528988
  • EAN: 7890797634143

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: Warning: Please read the product instructions carefully before use to ensure correct use.
序列号: 7890797634143

配送 & 退货

在 2 天内发货

  • STANDARD: 免费 - 之间的交付 周三 22 十月 2025–周三 29 十月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • Shenzhen Gujun Technology Co., Ltd.
  • Shenzhen Gujun Technology Co., Ltd.
  • 1303, 13/F, Tower B, TCL Building, No. 6 Gaoxin Nandao Road, Yuehai Street
  • Nanshan District
  • Shenzhen
  • Guangdong
  • CN
  • 518067
  • idyaiy16984@163.com
  • 13038870349
  • https://hengruigongju.1688.com/page/index.html?spm=0.0.wp_pc_common_header_companyName_undefined.0

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.ozon.ru/seller/topstore-600244/products/?miniapp=seller_600244&__rr=1&abt_att=1