描述
DC 6V-30V DDC-431 Relay Delay Digital Switch DC 12V Data Save Delay ControllerOOTDTYAtscribe:-Powerful function, with one-button emergency stop function (stop button), with protection against reverse connection, reverse connection, no combustion, memory power off.-Increased sleep mode, when power on, no operation within 5 minutes, automatically turn off the display, wake up any button!-You can set a variety of OP parameters, CL, LOP, these parameters are independent of each other, save the setting parameters automatically saving and other functions, almost meet all the needs! Product Instruction:Working Voltage: DC6V-DC30V (Wide Voltage Protection)Trigger Signal Source: DC 3.0V-24V High Level Trigger signal grounding and system grounding to improve the anti-interference ability of the system can also cause ground short circuitOutput Performance: DC 30V/10a or AC 250V/10a controllable equipmentProduct Size: 64mm*35mm*19.3mm Mounting Hole: 3mm Diameter Working Temperature: -40°C - 85°C Working Mode: P1 mode: when the signal is triggered, the relay turns on the OP time and then turns off; During OP time, the following operationP1.1: the signal is triggered again. P1.2: the signal restarts at the timeQ1.3: the signal restarts, the relay is disconnected, and the time stops. P-2: give trigger signal, when the relay turns off the CL time, the relay turns on the OP time. When the timing is complete, the relay is turned off. P3.1: give trigger signal, when the relay is turned on the OP time, the relay turns off the CL time, and then loops the above action, the signal is fed again in the cycle, the relay is disconnected, the time is stopped; The number of cycles (LOP) can be set P3.2: when the power is turned on, no trigger signal is required, the relay turns on the OP time, the relay turns off the CL time, and the above actions are cyclic; The number of cycles (LOP) can be set P-4: signal hold function, if there is a trigger signal, the time is cleared, the relay remains on; When the signal disappears, the relay is off after the OP time is set; During timing, a signal occurs and the time is cleared. Relay On Mode:ON: the relay can guide during OP conduction. Off: the relay cannot be turned on and is always off. Short press the STOP button on the main interface to switch between on and off. The current status will flash and then return to the main interface. This function is emergency stop function, one button to open and close the relay. Sleep mode (long press the stop button to display the current mode):C-P sleep mode: within five minutes, without any operation, the digital tube-shaped automatically shut down the display, the program works normally. Normal mode o-d: digital tube-shaped is always displayedPress and hold the STOP button for 2 seconds, then release to switch C-P and o-d states. The current status will flash and then return to the main interface. Timing range:How to select the time rangeAfter setting the parameter value in the mode selection interface, press the STOP button to select the czasu.XXX measurement range. The decimal point is in one place, time range: from 1 second to 999 secondsX X X decimal point out of ten, time range: from 0.1 seconds to 99.9 secondsX. X.X. The decimal point is fully illuminated, the time range is from 1 minute to 999 minutes. For example, if you want to set OP to 3.2 seconds, move the decimal point to ten digits, and the tube-shaped digital will display 03.2.Parameter description: OP on time, CL off time, LOP cycle number 1-999 times, "-" means infinite loopThese parameters are independent of each other, but each mode divides these parameters. For example, when the OP in time is set to 5 seconds in P1.1, the user wants to switch to P1.2 mode, and then when entering P1.2 setting the corresponding parameters, OP will also be 5 seconds Displaying 000 on the main interface and pressing the SET button will display OPL, LOP and corresponding time XXXif only OP in mode such as P1.1 mode, P1.2, P1.3 time, then short press the SET button will only display OP and the corresponding timeIf the mode has OP, CL, LOP, such as P3.1, P3.2 mode, short press the SET button will display OP and corresponding time, CL and corresponding time, LOP and corresponding timesAfter setting the mode, it is very convenient to view the parameters set in the current mode by pressing the set button on the main interface. How to set the parameters:1) first determine the relay working modeAccording to the relay working mode, in the main interface (when the module is powered on, the current working mode will flash (default mode P1.1), then enter the main interface "press and hold the SET button for 2 seconds and then release" to enter the mode selection. interface, select the mode to be set by short pressing up and down buttons.2) after selecting the mode to be set (for example, P3.2), press the set button to set the corresponding parameter. At this time, the set parameter will flash in time, CL off time, L
-
Fruugo ID:
397933486-848440651
-
EAN:
6935170125755