DC 6V-30V DDC-431 Timer Delay Relay Switch Digital DC 12V Data Save Delay Controller

MYR79.00
免费送货

DC 6V-30V DDC-431 Timer Delay Relay Switch Digital DC 12V Data Save Delay Controller

  • 品牌: Unbranded

DC 6V-30V DDC-431 Timer Delay Relay Switch Digital DC 12V Data Save Delay Controller

  • 品牌: Unbranded
建议零售价: MYR84.00
价格: MYR79.00
您节省了: MYR5.00 (5%)
由……售出:
MYR79.00
免费送货

有货

我们接受以下付款方式

描述

DC 12V DDC-431 Timer Delay Relay Switch Digital Data Save Delay Controller DC 6V-30V Description: - Powerful function, one-button emergency stop function (STOP button), with reverse connection protection, reverse connection without burning, power-off memory. - Increased sleep mode, after enabling, No operation within 5 minutes, automatically turn off the display, wake up any button! - You can set different OP, CL, LOP parameters, these parameters are independent of each other, save the setting parameters automatically power-down save and other functions, almost meet all needs! Product manual: Working voltage: DC6V-DC30V (wide voltage anti-connection protection) Trigger signal source: high-level trigger DC 3.0V24V signal ground and system ground to improve the system's anti-interference ability can also short-circuit the ground Output capacity: controllable DC 30V/10A or AC 250V/10A equipment Product size: 64mm*35mm*19.3mm Mounting hole: diameter 3mm Working temperature: -40 C ~ 85 C Operating mode: P1 mode: After the signal is triggered, the relay turns on the OP time, then turns off; in the OP time, the following operation P1.1: The signal is triggered again. P1.2: Signal triggers re-timed again P1.3: The signal triggers reset again, the relay is disconnected, and the timing is stopped. P-2: Give the trigger signal, after the relay turns off the CL time, the relay turns on the OP time. After the timing is completed, the relay is turned off. P3.1: Give the trigger signal, after the relay turns on the OP time, the relay turns off the CL time, then loops the above action, the signal is given again in the cycle, the relay is disconnected, the timing is stopped; the number of cycles (LOP) can be set P3.2: No trigger signal is required after power-on, the relay turns on OP time, the relay turns off CL time, and the above actions are cycled; the number of cycles (LOP) can be set P-4: Signal hold function If there is a trigger signal, the timing is cleared, the relay remains on; when the signal disappears, the relay is turned off after timing the OP; during the timing, there is a signal, and the timing is cleared. Relay enable mode: ON : The relay is allowed to conduct during the OP conduction time. OFF : The relay is prohibited from being turned on and is always off. Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash, then return to the main interface. This function is the emergency stop function, one button to open and close the relay. Sleep mode (long press the stop button to view the current mode): C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, the program runs normally. O-d normal mode: the digital tube is always on display Press and hold the STOP button for 2 seconds and then release to switch the C-P and O-d states. The current state will flash and then return to the main interface. Timing range: How to choose the timing range After setting the parameter value in the mode selection interface, press the STOP button to select the timing range. XXX. Decimal point is in one place, timing range: 1 second to 999 seconds XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds X.X.X. The decimal point is fully illuminated, the timing range is from 1 minute to 999 minutes. For example, if you want to set the OP to 3.2 seconds, move the decimal point to ten digits, and the digital tube displays 03.2. Parameter description: OP on time, CL off time, LOP cycle number 1-999 times, "---" stands for infinite loop These parameters are independent of each other, but each mode shares these parameters. For example, when the on-time OP is set to 5 seconds in P1.1, the user wants to switch to the P1.2 mode, then when entering the P1.2 setting corresponding parameters, the OP also Will be 5 seconds Displaying 000 on the main interface and pressing the SET button will display OPL, LOP and corresponding time XXX If only OP in the mode, such as mode P1.1, P1.2, P1.3 time, then short press SET button will only display OP and corresponding time If the mode has OP, CL, LOP such as mode P3.1, P3.2 short press SET button will display OP and corresponding time, CL and corresponding time, LOP and corresponding times After setting the mode, it is very convenient to view the parameters set in the current mode by pressing the SET button on the main interface. How to set parameters: 1) First determine the working mode of the relay According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), then enter the main interface "press and hold the SET button for 2 seconds and then release" to enter the mode selection. Interface, select the mode to be set
  • Fruugo ID: 100247484-210813223
  • EAN: 8456000426548

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark

配送 & 退货

在 24 小时内发货

  • EXPRESS: 免费 - 之间的交付 周五 10 十月 2025–周二 14 十月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • ShenZhenShiFuJingKeJiYouXianGongSi
  • ShenZhenShiFuJingKeJiYouXianGongSi
  • GuangMingXinQuGongMingJieDaoYuLvCunErQu206Hao911Fang
  • Shenzhen
  • China
  • 518106
  • uiyhfsd34h@hotmail.com
  • 19168536521

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • CrossStYAting
  • E-CrossStu GmbH
  • 69 Mainzer Landstrasse
  • Frankfurt am Main
  • Germany
  • 60329
  • E-crossstu@web.de
  • +4969332967674