描述
Delay Relay Module 2‑Channel Pulse Trigger YF‑7 DC7‑30V for Controling Solenoid Valve
Feature:
1. The delay relay module has 32 common functions, can meet more application needs
2. Suitable for controling solenoid valves, water pumps, motors and light strips, etc.
3. The time range is from 0.01 second to 999 minutes, any time can be adjusted
4. Adopted of high quality electronic components, and accuracy process, ensure for the durability
5. Professional design and reasonable structure, can control DC or AC load within 5A
Specification:
Item Type: Delay Relay Module
Model: YF-7
Input Voltage: DC 7~30V optional
Output Power: Can control DC or AC load within 5A
Time Range: 0.01 second to 999 minutes, any time adjustable
Wiring Port Description:
1. +: Input power positive
2. -: Input power negative
3. IN+: Positive signal input terminal
4. IN-: Negative signal input terminal
5. NO: The relay normally open interface, the relay is suspended before the pull-in, and short-connected to the COM after the pull-in
6. COM: Common interface of relay
7. NC: Normally closed interface of the relay, the relay is short-connected with COM before it is closed, and it is suspended after it is closed
List of Functions: You can set the functions arbitrarily after you buy them, and the manual is provided; any parameter set can be memorized when the power is off
All the functions in P-11 to P-44 are as follows; signal 1 corresponds to relay 1; signal 2 corresponds to relay 2; the two channels can be triggered at the same time; independent of each other; each other does not affect each other; each signal tube corresponds to each relay
P-11: Jog (to pull in the signal relay, the signal disappears and the relay stops)
P-12: Self-locking (turn on the signal relay once, and stop the signal relay again)
P-13: Give the signal, and the relay will automatically stop after closing for A second; triggering is invalid during the delay period
P-14: Give the signal, the relay will stop automatically for A second; trigger to re-timing during the delay period
P-15: Give the signal, the relay will stop automatically for A second; during the delay period, the superposition timer will be triggered
P-16: Give the signal, and the relay will stop automatically for A second; trigger reset during the delay period
P-17: Give the signal, the relay is closed, the input signal is disconnected, and the power is turned off after the start of timing A second, and the signal is kept output during the delay period, and the timing stops
P-18: After the power is turned on, the relay will be turned on immediately, and the power will be turned off after a delay of A seconds; until the next power on
P-21: Give the signal, after a delay of A second, the relay is closed
P-22: Give the signal, after more than A second, the relay is closed, the signal disappears, and the relay stops
P-23: After the signal disappears for more than A second, the relay is closed, the signal disappears, and the relay stops
P-24: There is a signal. After A second, the relay is closed. After the signal disappears for more than A second, the relay stops.
P-25: There is a signal. After A second, the relay is closed. When there is another signal for more than A second, the relay stops.
P-26: When there is a signal, the relay will stop after closing for A second, and when the signal disappears, the relay will stop after closing again for A second.
P-27: If there is a pulse signal, the relay stops; if there is no pulse signal, the relay will be closed for A second; (the signal continues or the signal disappears will be regarded as no pulse signal)
P-28: After power-on, after a delay of A seconds, the relay will be closed until the power is off
P-31: After power on, the relay is closed for A second, disconnected for B second, infinite loop; power off stops
P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop
P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop
P-34: After power-on, the relay will be closed after a delay of A seconds, and stop after being closed for B seconds
P-35: There is a signal, after a delay of A second, the relay will be closed, and the relay will be closed after being closed for B seconds.
P-36: When there is a signal, after A second, the relay will be closed, and after B second, the relay will stop, the signal disappears, and the timer will be cleared and stopped.
P-37: If there is a signal, the relay will stop automatically for A second when the relay is closed, and then it will count for B seconds after it stops. The signal trigger is invalid within the time A+B.
P-38: When there is a signal, the relay will automatically stop when it is closed for A second, and after stopping and counting for B seconds, i
-
Fruugo ID:
442512441-929084217
-
EAN:
7061262169334