Digital Incubator Temperature & Humidity Controller AC110-230V, 28x70mm

MYR74.00
+ MYR23.49 送货

Digital Incubator Temperature & Humidity Controller AC110-230V, 28x70mm

  • 品牌: Unbranded

Digital Incubator Temperature & Humidity Controller AC110-230V, 28x70mm

  • 品牌: Unbranded
建议零售价: MYR119.00
价格: MYR74.00
您节省了: MYR45.00 (37%)
由……售出:
MYR74.00
+ MYR23.49 送货

有货

我们接受以下付款方式

描述

Digital Incubator Temperature & Humidity Controller AC110-230V, 28x70mm

Incubator Temperature Controller Digital Hatchery Temperature Controller for Incubators Refrigerators 110‑220V Item Type: Incubator Temperature Controller Material: ABS Power Supply Voltage: AC110-230V Power Supply Frequency: 50/60Hz Temperature Measurement Range: -40-110℃ Temperature Measurement Accuracy: 0.3℃ Humidity Measurement Range: 0%-100%RH Humidity Measurement Accuracy: 3% Output Control: Relay Output Output Power: Mximum 10A Installation Hole Size: Approx. 28 x 70mm/1.1 x 2.8in Setup essential Start value <stop value (the program automatically determines that the working mode is heating/humidifying mode) Start value>Stop value (The program automatically determines that the working mode is cooling/dehumidifying mode) Heating/cooling mode setting Setting method: Setting (start temperature): long press the △1 button, the start temperature flashes, and set the start temperature value through the △1▽1 key Setting (stop temperature): long press the ▽1 button to stop the temperature flashing, and set the stop temperature value through the △1▽1 button. Heating use case: Control the water heater, stop heating to 70°C, start heating again when the temperature drops to 45°C, and cycle Step 1: Heating working mode, starting temperature <stop temperature Step 2: Long press the △1 button, the start temperature flashes, and set the start temperature to 45℃ by pressing the △1▽1 button. Step 3: Long press the ▽1 button to stop the temperature flashing, and set the stop temperature to 70℃ by pressing the △1▽1 button, and the setting is complete! If there is no operation for 10 seconds, it will automatically return to the normal display state. You can also press △2▽2 to exit immediately. Refrigeration use cases: Used in the breeding farm, the fan ventilation stops at 25℃, and the temperature rises to 30℃ to start ventilation again Step 1: Cooling mode, start temperature>stop temperature Step 2: Long press the △1 button, the start temperature flashes, and set the start temperature to 30℃ by pressing the △1▽1 button Step 3: Long press the ▽1 button to stop the temperature flashing, and set the stop temperature to 25℃ through the △1▽ button, and the setting is complete! If there is no operation for 10 seconds, it will automatically return to the normal display state. You can also press △2▽2 to exit immediately. Humidification/dehumidification mode setting Setting method: Setting (starting humidity): long press the △2 key, the start humidity value flashes, and set the start humidity value through the △2▽2 key. Setting (stop humidity): Long press the ▽2 key to stop the flashing of the humidity value, and set the stop humidity value through the △2▽2 key. Humidification example: To humidify the supermarket, control the humidifier to 50% RH to start humidifying, and to stop humidifying when humidified to 80% RH. Setting steps: Step 1: Long press the Δ2 key to start the humidity value flashing, and use the △2▽2 key to set the start humidity value to 50%RH Step 2: Long press the ▽2 key to stop the humidity value flashing, and set the stop humidity value to 80%RH through the △2▽2 key, and the setting is complete! Press the key for 10 seconds without operation, it will automatically return to the normal display state, or you can press the △1▽1 key to exit immediately. Dehumidification example: Workshop control exhaust dehumidification system, humidity 75%RH starts dehumidification, humidity 45%RH stops dehumidification Setting steps: Step 1: Long press the △2 key to start the humidity value flashing, and use the △2▽2 key to set the starting humidity value to 75%RH Step 2: Long press the ▽2 key to stop the humidity value flashing, and set the stop humidity value to 45%RH by pressing the △2▽2 key, and the setting is complete! Press the key for 10 seconds without operation, it will automatically return to the normal display state, or you can press the △1▽1 key to exit immediately. Temperature correction Temperature correction: Press the △1▽1 key at the same time for 5 seconds to start the temperature digital flashing, and it will display 00. Set the start temperature correction value through the △1▽1 key. After the setting is completed, press the button for 10 seconds without any operation, and it will automatically return to the normal display state. You can also press the △2▽2 button to exit immediately. Humidity correction Humidity correction: Press the △2▽2 key at the same time for 5 seconds to start the humidity number flashing, display 00, and set the start humidity correction value through the △2▽2 key. After setting, press the button for 10 seconds without any operation, and it will automatically return to the normal display state. You can also press △1▽1 to exit immediately.
  • Fruugo ID: 413143201-873222446
  • EAN: 9381337211026

配送 & 退货

在 24 小时内发货

  • STANDARD: MYR23.49 - 之间的交付 周三 10 十二月 2025–周五 19 十二月 2025

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659