描述
Please note that the price does not include customs duties!! Customs duties need to be borne by the buyer themselves.
Features:
1.Cost-effective Hantek PC USB 8CH Automotive Diagnostic Oscilloscope/DAQ/Programmable Generator: Highly efficient and cost -effective;
2.8 channels oscilloscope for vehicle testing;
3.Auto Ignition Probe;
4.2.4MSa/s real time sampling rate, 12bit vertical resolution;
5.Spectrum analysis function;
6.10mV/div to 5V/div input sensitivity;
7.DAQ card function;
8.8 channels programmable generator which can analog signals of crankshaft, camshaft, etc.
(1) Vehicle Testing
First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition.
Ignition: primary and secondary.
Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position.
Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus.
Performer: Petrol/Diesel.
Starter and charging circuits.
(2) Oscilloscope
8 channels oscilloscope, 2.4MSa/s real time sampling rate.
12 bits vertical resolution, spectrum analysis function.
(3) Programmable Generator
8 channels programmable generator.
Can analog signals of crankshaft, camshaft etc.
(4) Others
USB 2.0 interface plug and play, and no need extra power supply;
More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use.
NOTE: Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7,Window 8,Window 10.
Specifications:
Model: Hantek1008C
Oscilloscope Mode:
Vertical:
1.Analog Channel: 8
2.Input Impedance: Resistance: 1MΩ
3.Input Sensitivity: 10mV/div to 5V/div
4.Input Coupling:DC
5.Resolution: 12 bits
Horizontal:
6.Memory Depth: 4K
7.Max. Input: 400V (DC+AC Peak)
8.Real-Time Sampling Rate: 2.4MSa/s
9.Time Base Range: 1ns/div to 20000s/div(1-2-5 sequences)
10.Time Base Precision: ±50ppm
Trigger:
11.Source: CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8
12.Mode: Edge
X-Y Mode:
13.X-Axis Input: CH1
14.Y-Axis Input: CH2
Cursors and Measurement:
15.Voltage Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot
16.Time Measurement: Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
17.Cursors Measurement: Horizontal ,Vertical, Track, Auto Measure Modes
18.Waveform Signal Process: +,- , x,÷, FFT, Invert
19.Voltage Range: 10mV to 5V/div @ x 1 probe; 100mV to 50V/div @ x 10 probe; 10V to 5000V/div @ x 1000 probe; 100V to 50000V/div @ x 10000 probe; 200mV to 100V/div @ 20:1
20.Current Range: 100mA to 50.0A/div @ CC65(20A); 1000mA to 500.0A/div @ CC65(65A); 1A to 100.0A/div @ CC650(60A); 10A to 1000.0A/div @ CC650(650A); 1A to 200.0A/div @CC1100(100A); 10A to 2000.0A/div @CC1100(1100A)
21.Cursor: Time/frequency difference, voltage difference
22.FFT: Rectangular, Hanning, Hamming, Blackman Window
23.Math: Addition, subtraction, multiplication, division
Programmable Generator
24.Channel: 8
25.Output Level: LVTTL
26.Frequency Range: 0-250kHz
27.Interface: USB 2.0
28.Power: No need extra power supply
29.Size: 185 x 150 x 27 (mm)
-
Fruugo ID:
299221753-669775063