High Precision Digital Multimeter, Inductance, Capacitance and Resistance Tester, LCR with NCV Function

RM139.00
FREE Shipping

High Precision Digital Multimeter, Inductance, Capacitance and Resistance Tester, LCR with NCV Function

  • Brand: Unbranded

High Precision Digital Multimeter, Inductance, Capacitance and Resistance Tester, LCR with NCV Function

  • Brand: Unbranded
RRP: RM189.00
Price: RM139.00
You save: RM50.00 (26%)
Sold by:
(Premium Seller)
RM139.00
FREE Shipping

In stock

14-Day Returns Policy

Payment methods:

Description

High Precision Digital Multimeter, Inductance, Capacitance and Resistance Tester, LCR with NCV Function

Feature: 1. [High Accuracy Digital Multimeter] This multimeter offers minimal errors and ensures accurate measurement data, making it a reliable tool for various measurement tasks. 2. [NCV Function] Equipped with a non contact voltage (NCV) feature, this multimeter allows for safe and convenient voltage measurements without direct contact. 3. [Compact and Portable] With a compact body, this inductance capacitance resistance tester is easy to carry, making it convenient for travel maintenance tasks. 4. [Backlit Screen Display] The LCR meter features a backlit screen that provides clear visibility, allowing for easy reading of measurements in any complex or dark environment. 5. [User Friendly] The digital multimeter is designed with clear markings, enabling even beginners to quickly and easily start using the device. Specification: Item Type: Digital Multimeter Material: ABS Battery Model: 1.5V AAA Battery x 2 (Not Included) Battery Type: Dry Battery DC Voltage (V)(mV): 6V 60V 600V 1000V 60mV 600mV Accuracy: ±(0.5%+3) AC Voltage (V)(mV): 6V 60V 600V 750V 60mV 600mV Accuracy: ±(1%+3) DC Current (A)(mA): 6A 10A 60mA 600mA Accuracy: ±(1.2%+3) AC Current (A)(mA): 6A 10A 60mA 600mA Accuracy: ±(1.5%+3) Inductance: 6mH Accuracy: ±(5%+50) 60mH 600mH 6H Accuracy: ±(3%+10) 60H Accuracy: ±(5%+50) Resistance: 600Ω 6kΩ 60kΩ 600kΩ 6MΩ Accuracy: ±(0.5%+3) 60MΩ Accuracy: ±(1.5%+3) Capacitance: 6nF 60nF 600nF Accuracy: ±(5%+20) 6μF 60μF 600μF Accuracy: ±(2%+5) 6mF 60mF Accuracy: ±(5%+5) Frequency: 99.99Hz 999.9Hz 9.999KHz 99.99KHz 999.9KHz 10MHz Accuracy: ±(0.1%+2) Duty Ratio: 1%~99% Accuracy: ±(0.1%+2) Continuity: <50Ω Diode: Forward DC Current About 5mA, Voltage About 3.9V Temperature: -20~1000℃ -4~1832℉ Accuracy: ±(2.5%+5) Preparation 1. When using the instrument, users must adhere to standard safety rules: General guard against electric shock Prevent misuse of the instrument 2. Upon receiving the instrument, check for any damage during transport 3. After storing and shipping in rough conditions, check and confirm if the instrument is damaged 4. The test cables must be in great condition. Before use, check if the insulation of the test cables is damaged and if the metal wire of the leads is exposed 5. Using the test cables provided with the instrument can ensure safety, and if needed, they must be replaced with the same or equivalent grade of test cables Use 1. When using, make sure to use the correct function and range 2. Do not exceed the indicated values for the guard range of each range during measurement 3. When connecting the instrument to the measuring circuit, do not touch the tip (metal part) of the test cables 4. During measurement, if the measured voltage is higher than 60V DC or 30V AC (rms), pay attention to keep your fingertips behind the test cable guard 5. Do not measure voltage if the voltage between the measurement terminal and ground exceeds AC1000V 6. Before rotating the selector switch to change the measurement function, remove the test leads from the measured circuit 7. Do not measure resistance, capacitance, diodes, and circuit continuity with electricity 8. During the current, resistance, capacitance, diode, and line on off test range, care should be taken to avoid connecting the instrument to a voltage source 9. Before the capacitor is completely discharged, do not measure the capacitance 10. Do not use this instrument near explosive gases, vapors, or dust 11. If any abnormalities or malfunctions are noticed in the instrument, it should be stopped from use 12. Unless the instrument bottom shell and battery cover are completely fastened in place, the instrument should not be used. Package List: 1 x Digital Multimeter 1 x Cloth Bag 2 x Test Cable 1 x Temperature Probe 1 x User Manual
  • Fruugo ID: 413875476-874569661
  • EAN: 7908770780906

Product Safety Information

Please see the product safety information specific to this product outlined below

The following information is provided by the independent third-party retailer selling this product.

Product Safety Labels

CE Mark
Safety Warnings: Warning: Please read the product instructions carefully before use to ensure correct use.
Serial Number: 7908770780906

Delivery & Returns

Dispatched within 2 days

  • STANDARD: FREE - Delivery between Mon 12 January 2026–Mon 19 January 2026 - FREE

Shipping from China.

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy

Product Compliance Details

Please see the compliance information specific to this product outlined below.

The following information is provided by the independent third-party retailer selling this product.

Manufacturer
The following information outlines the contact details for the manufacturer of the relevant product sold on Fruugo.

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

Responsible Person in the EU
The following information outlines the contact information for the responsible person in the EU. The responsible person is the designated economic operator based in the EU who is responsible for the compliance obligations relating to the relevant product sold into the European Union.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795