The default voltage of the sensor is DC5V! If you need 24 V, please be sure to leave us a message!
KA800 open magnetic linear displacement sensor can be applied to digital display DRO and industrial control automation of various machine tools. It is easy to install, arbitrary cutting length, arbitrary pasting, no fear of oil cooling fluid, long service life, reproducibility up to 0.005mm, non-contact relative displacement principle, no wear and tear! Don"'"t worry that he will absorb iron pins. This will not affect its work. Many of our customers have proved that it can be used for ten years.
ka800
Special note:
KA800MC magnetic head should be used in conjunction with TR50 magnetic grating ruler. When ordering, two pieces need to be purchased at the same time. TR50 magnetic grid scale one meter per unit price!
Product Brief
Ka800mc-5 magnetic gate ruler is mainly suitable for middle and low precision
Wood, stone, machine tools, digital display, etc. need to be processed and measured.
Location and measurement in material processing.
Ulnar band TR50 at 5 + 5mm intervals
Use stainless steel belt, smooth paste
Special aluminum shell and special protective steel
Adhesive tape makes the tape better anti oil and waterproof.
Dust prevention, improve the service life.
Small volume, reading head, small space, easy to install.
1) suitable for: 9 core socket RS-422 signal output.
2) suitable for: 9 core socket TTL signal output.
FG: shielded metal case
mechanical properties
Metal zinc alloy shell reading head.
Three installation holes fixed reading head.
The range of installation tolerances is large.
Electrical characteristics
TTL5V signals have line driven output,
Wire using metal shields, more super
Strong anti-interference ability.
The signal has good stability.
Maximum speed 5m/s
technical parameter
Reference signal per 5mm (C)
Ruler band specification 5+5mm
Resolution 5 mu m
Accuracy (0.035 + 0.02 x L) mm, L as an effective meter
The length of the unit is m
Reproducible + 1 pulses
Cable 5 core or 8 core
Output form TTL or RS-422
Cable (3 meters in standard length)
Between the reading head and the protective steel strip
gap
0.8 ~ 1.8mm
Minimum winding radius 60mm power supply voltage 5VDC + 5%
Connection line signal consumption current (no load) 40mAMAX
Green A
Consumption of current (with load)
120mAMAX (5V, RL=120 omega)
60mAMAX (28V, RL =1.2k omega)
Orange B
Green black A
Orange black B
Red +5V phase shift 90 + 5 degrees
Black 0V
Maximum speed 5m/s (MS T 5)
Shielded line P
Anti vibration 100m/s2[10Hz ~ 2000Hz]
Anti impact 1000m/s2 (11ms)
The standard reading head provides 3M cable.
Long cable can be provided as required.
The big line length is as follows:
LMAX=50m (read head and cable)
LMAX=100m (3m read head cable + extension
Long cable)
Read head protection level IP 67 DIN 40050/IEC 529
Working temperature -20 degree to 85 degrees C
Storage temperature from -20 to 85 degrees C
Moisture 100% does not condense
Reading head weight 150g
Polarity reversal protection and output short-circuit current protection for electrical protection power supply
Technical parameters of ulnar belt
Ruler band specification 5+5mm
The precision 0.02mm/m at 20 degrees
Width 10mm
Thickness 1.45MM
Maximum measurement length 100m
Expansion coefficient 10.5*10-6/k
Minimum bending half - channel 130mm
Operating temperature -20 degree ~70 degrees
Storage temperature -40 degree ~90 degrees
Installation tolerances of sensors and magnetic rulers
-
品牌:
Unbranded
-
类别:
仪表仪器
-
大小:
Combination 3
-
Fruugo ID:
237369356-508670047
-
EAN: