Motor Forward / Reverse Control Board Two Relay Delay Timing Cycle Module

MYR129.00
免费送货

Motor Forward / Reverse Control Board Two Relay Delay Timing Cycle Module

  • 品牌: Unbranded

Motor Forward / Reverse Control Board Two Relay Delay Timing Cycle Module

  • 品牌: Unbranded
建议零售价: MYR179.00
价格: MYR129.00
您节省了: MYR50.00 (27%)
由……售出:
MYR129.00
免费送货

有货

我们接受以下付款方式

描述

Features 1、Brand new and high quality 2、6 kinds of commonly used functions to meet the needs of more applications; 3、It can control 2‑way solenoid valve, pumps, motors, lights and other running freely 4、Output power: it can control within 30A DC or AC load 5、Time range: 0.1 seconds to 999 minutes any time adjustable Specification Features: Brand new and high quality 6 kinds of commonly used functions to meet the needs of more applications; It can control 2-way solenoid valve, pumps, motors, lights and other running freely Output power: it can control within 30A DC or AC load Time range: 0.1 seconds to 999 minutes any time adjustable Specification: Time range: 0.1 seconds to 999 minutes Weight: Approx.110g/3.9oz Wiring port Description: 3. IN1: Signal input 1 (negative trigger) 4. IN2: Signal input terminal 2 (negative trigger) 2. IN3: Signal input 3 (negative trigger) 5. NO: relay normally open interface, relay pull before the suspension, after the connection with the COM shorted 6. COM: relay common interface 7. NC: relay normally closed interface, the relay before the connection with the COM shorted, pull after the suspension Function list: P - 1: to signal 1, relay 1 pulls to A time automatically stops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is emergency stop reset signal P - 2: signal 1, relay 1 is pulled to A time automatically stop; relay 2 from the signal to start delay B time after the suction to C time automatically stop (this function time unit needs to be consistent) P - 3: After power on, relay 1 pulls up to A time release, waiting for C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns endless operation endless cycle (If the control motor is reversible can be understood as: the motor is running a period of time; stop for some time; automatically reverse for some time; stop for some time; then automatically forward; P - 4: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops and starts counting to A time relay 2 pull; to signal 3 (limit), relay 2 stops and starts timing To B time relay 1 pull; infinite loop (If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 to stop a period of time; then automatically forward; P - 5: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop and start timing to A time relay 2 pull; give signal 3 (limit), relay 2 stop; Signal 1; once again (If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 stop; give the signal 1; P-6: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop; give signal 1, relay 2 pull; to signal 3 (limit), relay 2 stop; (If the control motor is reversible can be understood as: press the start button 1; go to the limit 2 stop; press the start button 1 again; reverse to the limit 3 stop; If the remote control function: remote control A key and B key to start the above function; C key press the relay 1 work (forward); then press the relay 1 to stop (stop); D key press the relay 2 work (reverse); Press once relay 2 to stop (stop); Key Settings Description: Power display "----" that access to standby; Press the first time K1, the screen shows: P-1: K2 and K3 adjustment mode Press the second time K1, the screen shows: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit) Press the third time K1, the screen shows: B001: K2 and K3 adjust the second time B, K4 adjust the decimal point (time unit) Press the fourth time K1, the screen shows: C001: K2 and K3 adjust the third time C, K4 adjust the decimal point (time unit) Press the fifth K1, display "----" that entered the standby state; For example; need to set the mode: P - 2; time: A010 B005 C006: Indicating the second mode of operation; after the signal 1; relay 1 after 10 seconds to start off; relay 2 to give the signal after delay 5 seconds after the start 1 second automatically shut down Decimal time unit Description: XX.X decimal point in the ten, timing range: 0.1 seconds to 99.9 seconds XXX no decimal point, timing range: 1 second to 999 seconds XXX. Decimal points in a single, timing range: 1 minute to 999 minutes Package list: 1 x Motor Control Board Package List
  • Fruugo ID: 339985280-745790841
  • EAN: 6117160241274

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

配送 & 退货

在 2 天内发货

  • STANDARD: 免费 - 之间的交付 周二 07 十月 2025–周一 13 十月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策