描述
Feature:1. EXCELLENT PERFORMANCE: MDP series high voltage differential probe has ultra low bottom noise, excellent amplitude frequency characteristics, and higher common mode rejection ratio in the industry, helping you easily handle various high frequency and high voltage signal tests.2. EXCELLENT AMPLITUDE FREQUENCY CHARACTERISTICS: MDP series has excellent bandwidth flatness, with amplitude fluctuations of less than 0.5dB within half of the bandwidth, and can maintain the accuracy of signal testing in the high frequency range.3. 5MHZ BANDWIDTH LIMITATION: Used for measuring the switching frequency of FETs in most switching power supplies, effectively filtering out high frequency noise and interference.4. 1 CLICK ADJUSTMENT: Short circuit the differential probe probe, press the 0 button, and the differential probe can quickly complete 0 adjustment5. DUAL RANGE: Supports dual range switching, effectively improving signal to noise ratio and meeting more testing circuit requirements.6. UNIVERSAL BNC, OVERVOLTAGE ALARM: Universal standard BNC interface, can be used with all brands of oscilloscopes; When the voltage is overloaded, the range LED light will continuously flash, and the buzzer will continuously emit a drip drip sound, making you feel at ease in use.7. SMALL SIZE AND EXQUISITE APPEARANCE: With a thickness of only 2CM, the probe completely bid farewell to the clumsy appearance of traditional differential probes; The volume design is smaller and the appearance is more exquisite.Specification:Item Type: Oscilloscope High Voltage Differential ProbeMode: MDP700Material: ABS Bandwidth: 100MHzRise Time: Less than or equal to 3.5nsAttenuation: 20X, 200XAccuracy: 2%Maximum Input Division Voltage (DC and AC pk):70V (20X)700V (200X)Maximum Voltage to Ground:CAT I 600VCAT lI 450VBottom Noise:Full Bandwidth:20X: Less than or equal to 0.9mVrms200X: Less than or equal to 0.4mVrms5MHz Bandwidth Limit:20X: Less than or equal to 0.4mVrms200X: Less than or equal to 0.35mVrmsCommon Mode Rejection Ratio:DC: Greater than -80dB100kHz: Greater than -60dB10MHz: Greater than -30dB100MHz: Greater than -26dBDelay Time:11.99ns (20X)12.27ns (200X)Input Impedance:16M 1.5pF (differential)8M 3pF (single end to ground)Output Voltage: Less than or equal to 3VPower: 2WPower Supply: Type C interfaceOverload Indication: LED alarm, buzzerSize:Control Module: Approx. 91 x 33 x 15mm / 3.58 x 1.3 x 0.59inSignal Box: Approx. 100 x 36 x 20mm / 3.94 x 1.42 x 0.79inInput Line Length: Approx. 8cm / 3.1in (manual measurement may have slight errors)Output Line Length: Approx. 120cm / 47.2in (manual measurement may have slight errors)Temperature:Working State: 0 to 40 Non Working State: -30 to 70 Humidity:Working State: 5% to 85% RH (0 to 40 )Non Working State: 5% to 85% RH (Less than or equal to 40 ); 5% to 45% RH (40 to 70 ).Package List:1 x Probe Host 2 x Crocodile Clip 1 x Type C Cable 1 x Manual 2 x Retractable IC Clip Note:1. Before starting the measurement, it is necessary to calibrate the 0 point of the probe.First, short circuit the two input terminals, power on, lightly press the "0" button, alternately flash the gear indicator light, flash the 5 MHz indicator light, and the probe emits a "beep" sound, indicating successful calibration; When the probe emits three short 'beeps', it indicates calibration failure and needs to be recalibrated.2. When connecting the differential probe to the oscilloscope, it is recommended that the bandwidth of the oscilloscope should not be less than 100MHz and the channel input impedance should not be less than 1M.3. It is recommended to preheat the machine for 10 minutes before use to obtain more accurate data.4. When the gear indicator light of the probe keeps flashing and emits an incisive beep, it is a phenomena of overvoltage warning and should be switched to a high gear.
-
Fruugo ID:
387492725-831850247
-
EAN:
6950044993230