描述
Features: _x000D_
The Vehicle Loop Detector is mainly used to detect the existence and passing of vehicles _x000D_
Reset Switch: The reset switch enables the detector to be manually reset during commissioning and testing. This results in the detector re-tuning the sensing loop and becoming ready for vehicle detection_x000D_
_x000D_
Selectable Pulse Time: This feature sets the length of time that the pulse relay will be energized for 1 Second or 0.5 Seconds _x000D_
Pulse Relay Selection: The Pulse Relay may be configured to energize on detection of a vehicle or when the vehicle leaves the loop _x000D_
Sensitivity Boost : This feature sets the undetected level to maximum sensitivity and is used to prevent loss of detection of high-bed vehicles _x000D_
_x000D_
Switch Selectable Sensibility: 4 sensitivity setting are available on the switches to allow flexibility in configuration _x000D_
Switch Selectable Frequency: 4 frequency settings are available to prevent cross-talk between adjacent loops_x000D_
_x000D_
Filter Option: This option is used to provide a delay between detection of the vehicle and switching of the output relay . This relay is normally used to prevent false detection of small or fast moving objects_x000D_
_x000D_
Permanent Presence Option : This feature ensure detection of the vehicle will be maintained when the vehicle is parked over the loop for extended periods . _x000D_
_x000D_
_x000D_
Specifications: _x000D_
Supply voltage_x000D_
220VAC_x000D_
_x000D_
Power_x000D_
4.5VA_x000D_
_x000D_
Output relays_x000D_
240V/5A_x000D_
_x000D_
Operating temperature_x000D_
-20~65C_x000D_
_x000D_
Storage temperature_x000D_
-40~85C_x000D_
_x000D_
Frequency range_x000D_
20 kHz to 170 kHz_x000D_
_x000D_
Temperature compensation_x000D_
50C/ h_x000D_
_x000D_
Reaction time_x000D_
10ms_x000D_
_x000D_
Signal holding time_x000D_
Unlimited/limited_x000D_
_x000D_
Sensitivity_x000D_
Higher:0.02%_x000D_
high:0.05%_x000D_
low:0.1%_x000D_
lower:0.5%_x000D_
_x000D_
Loop inductance_x000D_
Total loop plus connection wiring:_x000D_
50H to 1000H. Ideal is 100H to 300H_x000D_
_x000D_
Loop connection wiring_x000D_
200 meters long. The total resistance is less than 80hm, twisted at least 20 times per meter_x000D_