Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

MYR239.00
免费送货

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

  • 品牌: Unbranded

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

  • 品牌: Unbranded
建议零售价: MYR299.00
价格: MYR239.00
您节省了: MYR60.00 (20%)
由……售出:
MYR239.00
免费送货

有货

我们接受以下付款方式

描述

Features 1、PROGRAMMABLE FUNCTION: This offline sequence controller has programmable function, which can be customized to set up a great sequence trace according to actual requirements. 2、BASIC VALUES: This programmable offline sequence controller has an operating voltage of DC12 to 24V, a screen structure of 5 digits and a high brightness digital tube. 3、USE SCENARIO: Our programmable off line serial controller is widely applied in industrial automation control, small mechanical devices. 4、MADE OF PC MATERIAL: The programmable offline sequence controller is made of PC material, which is strong and durable. 5、LIGHT WEIGHT: Our programmable offline sequence controller is light weight and easy to install and very practical and helpful. Specification Item Type: Programmable controller Material: PC Housing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H) Screen Structure: 5 digit, high brightness digital tube Operating Environment: -5℃- 60℃ (no condensation) Opening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W) Input: 5 programmable inputs, 2 fixed inputs Serial number Function Range Default value F0 Cycle working times Unit: times (demonstrated below) 0-65534, 65535 for countless times 1 F1 Number of rows at the beginning of the loop Unit: rows (Demonstrated below) 0-40 0 If the number of lines at the beginning of the loop > the number of lines at the end of the loop, it is illegal. Will alarm F2 Number of rows at the end of the loop Unit: rows (demonstrated below) 0-40 40 Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarm F3 Open [Output] manual debugging interface (restart to exit automatically or press [Return]) Introduced below 0 F4 Open [Input] manual debugging interface (restart to exit automatically or press [Return]) Introduced below 0 F5 Turn on programming mode (restart to exit automatically) 0-1 0 If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm 0: Turn off programming privileges (power off automatically changes to 0) 1: Turn on programming privileges F15 Adjust the amplitude value of [overall working time] during operation Unit:second 0-65535.999 , 0=no speed change during operation 0 F16 Auto run at power on specified program line: 31-40 lines 0-2 0 0 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category 1 Power on automatically runs program segment 31-40 lines. 2 The power on automatically works. F17 Action when ESC emergency stop key is pressed 0-2 0 0 Program ends and turns off all outputs 1 Program ends and holds current state 2 Program ends and runs program segment lines 31-40 If parameter 2 is not selected, then program lines 31-40 automatically act as normal program categories F18 Selectively switch P interface or F interface 0-3 0 1 Off [P interface] on [F interface] 2 On [P interface] off [F interface] 3 All off (temporary open: press [Set] key before power on) 0 All on F19 Main interface display content 0-2 0 0 Realtime working status. Display the total number of working times (not the number of cycles) under standby 1 Displays the number of cycles (not the total number) 2 Displays what line of program the system is running F20 Port filtering time of input port 0-65535 120 Set again when there is external interference. The higher the value, the slower the response Unit: Level F21 Start or emergency stop button signal filtering time on the panel 0-65535 27 Set again when there is external interference. The higher the value, the slower the response Unit: Level F24 Restore the factory setting 0-4 4 Note: After changing this parameter, you need to power off and restart 1 Restore [F] parameter only 2 Restore [P] parameter only 3 Restore all 4 No need to restore 0 or >10: restore all and open self test mode, factory mode (only for factory use) Package List 1 x Programmable Controller
  • 品牌: Unbranded
  • 类别: 医疗
  • Fruugo ID: 341992886-749632391
  • EAN: 6117160765190

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

配送 & 退货

在 2 天内发货

  • STANDARD: 免费 - 之间的交付 周三 08 十月 2025–周二 14 十月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策