Features:
1、PROGRAMMABLE FUNCTION: This offline sequence controller has programmable function, which can be customized to set up a great sequence trace according to actual requirements.
2、BASIC VALUES: This programmable offline sequence controller has an operating voltage of DC12 to 24V, a screen structure of 5 digits and a high brightness digital tube.
3、USE SCENARIO: Our programmable off line serial controller is widely applied in industrial automation control, small mechanical devices.
4、MADE OF PC MATERIAL: The programmable offline sequence controller is made of PC material, which is strong and durable.
5、LIGHT WEIGHT: Our programmable offline sequence controller is light weight and easy to install and very practical and helpful.
Specification:
Item Type: Programmable controller
Material: PC
Housing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H)
Screen Structure: 5 digit, high brightness digital tube
Operating Environment: -5℃- 60℃ (no condensation)
Opening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W)
Input: 5 programmable inputs, 2 fixed inputs
Serial number
Function
Range
Default value
F0
Cycle working times Unit: times (demonstrated below)
0-65534, 65535 for countless times
1
F1
Number of rows at the beginning of the loop Unit: rows (Demonstrated below)
0-40
0
If the number of lines at the beginning of the loop > the number of lines at the end of the loop, it is illegal. Will alarm
F2
Number of rows at the end of the loop Unit: rows (demonstrated below)
0-40
40
Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarm
F3
Open [Output] manual debugging interface (restart to exit automatically or press [Return])
Introduced below
0
F4
Open [Input] manual debugging interface (restart to exit automatically or press [Return])
Introduced below
0
F5
Turn on programming mode (restart to exit automatically)
0-1
0
If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm
0: Turn off programming privileges (power off automatically changes to 0)
1: Turn on programming privileges
F15
Adjust the amplitude value of [overall working time] during operation
Unit:second
0-65535.999 , 0=no speed change during operation
0
F16
Auto run at power on specified program line: 31-40 lines
0-2
0
0 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category
1 Power on automatically runs program segment 31-40 lines.
2 The power on automatically works.
F17
Action when ESC emergency stop key is pressed
0-2
0
0 Program ends and turns off all outputs
1 Program ends and holds current state
2 Program ends and runs program segment lines 31-40
If parameter 2 is not selected, then program lines 31-40 automatically act as normal program categories
F18
Selectively switch P interface or F interface
0-3
0
1 Off [P interface] on [F interface]
2 On [P interface] off [F interface]
3 All off (temporary open: press [Set] key before power on)
0 All on
F19
Main interface display content
0-2
0
0 Realtime working status. Display the total number of working times (not the number of cycles) under standby
1 Displays the number of cycles (not the total number)
2 Displays what line of program the system is running
F20
Port filtering time of input port
0-65535
120
Set again when there is external interference. The higher the value, the slower the response Unit: Level
F21
Start or emergency stop button signal filtering time on the panel
0-65535
27
Set again when there is external interference. The higher the value, the slower the response Unit: Level
F24
Restore the factory setting
0-4
4
Note: After changing this parameter, you need to power off and restart
1 Restore [F] parameter only
2 Restore [P] parameter only
3 Restore all
4 No need to restore
0 or >10: restore all and open self test mode, factory mode (only for factory use)