Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12?24V
Item Type: Programmable controller
Material: PC
Housing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H)
Screen Structure: 5 digit, high brightness digital tube
Operating Environment: -5- 60 (no condensation)
Working Voltage: DC12-24V, >1.5A, power supply
Opening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W)
Output: 5 outputs the number of lines at the end of the loop, it is illegal. Will alarm
F2Number of rows at the end of the loop Unit: rows (demonstrated below)0-4040
Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarm
F3Open [Output] manual debugging interface (restart to exit automatically or press [Return])Introduced below0
F4Open [Input] manual debugging interface (restart to exit automatically or press [Return])Introduced below0
F5Turn on programming mode (restart to exit automatically)0-10
If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm
0: Turn off programming privileges (power off automatically changes to 0)
1: Turn on programming privileges
F15Adjust the amplitude value of [overall working time] during operation
Unit:second0-65535.999 , 0=no speed change during operation0
F16Auto run at power on specified program line: 31-40 lines0-20
0 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category
1 Power on automatically runs program segment 31-40 lines.
2 The power on automatically works.
F17Action when ESC emergency stop key is pressed0-20
0 Program ends and turns off all outputs
1 Program ends and holds current state
2 Program ends and runs program segment lines 31-40
If parameter 2 is not selected, then program lines 31-40 automatically act as normal program categories
F18Selectively switch P interface or F interface 0-30
1 Off [P interface] on [F interface]
2 On [P interface] off [F interface]
3 All off (temporary open: press [Set] key before power on)
0 All on
F19Main interface display content 0-20
0 Realtime working status. Display the total number of working times (not the number of cycles) under standby
1 Displays the number of cycles (not the total number)
2 Displays what line of program the system is running
F20Port filtering time of input port 0-65535120
Set again when there is external interference. The higher the value, the slower the response Unit: Level
F21Start or emergency stop button signal filtering time on the panel 0-6553527
Set again when there is external interference. The higher the value, the slower the response Unit: Level
F24Restore the factory setting 0-44
Note: After changing this parameter, you need to power off and restart
1 Restore [F] parameter only
2 Restore [P] parameter only
3 Restore all
4 No need to restore
0 or >10: restore all and open self test mode, factory mode (only for factory use)
-