描述
Feature:
1. This AC parameter communication module is mainly used to measure AC voltage, current, active power, frequency, power factor and active energy.
2. The module has no display function and the data is read through the TTL interface.
3. Support for Modbus-RTU standard protocol, including host computer software.
4. Comes with TTL to USB data cable and external CT.
5. The module works for Windows operating systems.
Specification:
Item Type: Communication Module
Measurement Range: AC 80-260V
Resolution: 0.1 V
Accuracy:0.5%
2. Current:
Measurement Range:0-100A
Resolution: 0.001 A
Accuracy: 0.5%
3. Active Power
Measurement Range:0-2.3 KW
Min. Measuring Power: 0.4W
Resolution: 0.1W
4. Power Factor
Measurement Range: 0.00-1.00
Resolution: 0.01
Accuracy:1%
5. Frequency
Range:45 Hz-65 Hz
Resolution: 0.1 Hz
Accuracy: 0.5%
6. Active Electrical Energy
Metering Range:0-9999.99 kWh
Resolution: 1Wh
Accuracy: 0.5%
Communication Protocol:
1. Physical layer protocol:
Physical layer adopts UART to TTL communication interface
Baud rate:9600,8 bit data bit,1 bit stop bit, no check
2. Application layer protocol
The application layer supports for Modbus-RTU protocol for communication and currently only supports function codes such as 0x03 (read-hold register), 0x04 (read-input register), 0x06 (write single register), 0x41 (calibration), 0x42 (power zero).
The 0x41 function code is limited to internal use (the address can only be 0xF8), used for factory calibration and back-to-factory maintenance, add a password of 16 bits after the function code, the password default is 0x3721.
The address range of the slave computer is 0x01 ~ 0xF7, and the address 0x00 is used as the broadcast address. The slave computer does not need to reply to the host, and the address 0xF8 is used as the general address. The address can only be used in a single-slave environment and can be used for calibration and other operations.
3. Read the results of the measurement
The command format for the host to read the result of the measurement is (8 bytes in total):
Slave computer address + 0x04 + register address high byte + register address low byte + register number high byte + register number low byte + CRC check high byte + CRC check low byte.
Reply of slave computer to the following command format is divided into two types:
Correct reply: Slave computer address + 0x04 + bytes + registers 1 data high byte + registers 1 data low byte +...+ CRC check high byte + CRC check low byte.
Wrong reply: Slave computer address + 0x84 + exception code + CRC check high byte + CRC check low byte.
The exception code is read as follows (the same below):
0x01, illegal function; 0x02, illegal address; 0x03, illegal data; 0x04, slave error.
The register layout of the measured results is shown in the following table:
v\:* {behavior:url(#default#VML);}
o\:* {behavior:url(#default#VML);}
x\:* {behavior:url(#default#VML);}
.shape {behavior:url(#default#VML);}
Register address
Description
Resolution
0x000
Voltage value measurement
1LSB corresponds to 0.1V
0x001
Current Measurement Value Low 16 Bits
1LSB corresponds to 0.01A
0x0002
Current Measurement Value High 16 Bits
0x0003
Power Measurement Value Low 16 Bits
1LSB corresponds to 0.1W
0x0004
Power Measurement Value High 16 Bits
0x0005
Energy Measurement Value Low 16 Bits
1LSB corresponds to 1Wh
0x0006
Energy Measurement Value High 16 Bits
0x0007
Frequency Measurement Value
1LSB corresponds to 0.1Hz
0x0008
Power Factor Measurement Value
1LSB corresponds to 0.01
0x0009
Alarm State
0xFFFF alarm,0x0000 no alarm
4. Read and modify the slave parametersIt supports reading and modifying the address and power alarm settings of the slave machine
5. Zero power
6. Calibration
7. CRC check
Package List:
1 x Module1 x Data Cable1 x CT1 x User Manual
Note:
The module TTL interface is a passive interface, it needs external 5V power supply, all 4 ports must be linked at the time of communication, otherwise it can't communicate.
-
Fruugo ID:
413522675-873947086
-