描述
Wall-mounted Light Intensity Illumination Temperature And Humidity Transmitter Sensor Environment Test For Greenhouse
1It is widely used in agricultural greenhouses, flower cultivation and other occasions requiring light intensity, temperature and humidity monitoring. 2Wall-mounted, easy installation, and the small volume will help saving your space. 3Compact and portable design, high density material shell, closed moisture-proof effect is significant. 4Exquisite welding circuit board, automatic manipulator welding process, to ensure the circuit board signal stability and accuracy, long-term reliable. 5High quality optical components, close to the visual sensitivity of the spectral characteristics, a wide range of luminance can be determined by 1 lx with high precision. 6With 485 communication, standard modbus-rtu communication protocol, communication address and baud rate can be set, the maximum communication distance is 2000m/6561.7ft. 7Powered by 0-30V DC wide voltage, low power consumption, energy saving. 8Waterproof design, it can be used indoors and outdoors to meet more needs of customers.
Condition: 100% Brand New
Item Type: Light Intensity Temperature Humidity Transmitter
Material: Polyester Plastics
Color: As shown in the picture
Size: Approx.13x11.7x5.5cm / 5.1x4.6x2.2in
Weight: Approx.208g/7.3oz
DC Power Supply (default): 10-30V DC
Maximum Power Consumption: 0.4W
Humidity Accuracy: 3%RH (5%RH~95%RH, 25C)
Temperature Accuracy: 0.5C (25C)
Light intensity Accuracy: 7% (25C)
Light Intensity Range: 0-200,000 Lx
Temperature and Humidity Range: -40 C ~ +60 C, 0% RH ~ 80% RH
Long-term Stability Temperature: 0.1C/y
Long-term Stability Humidity: 1%/y
Long-term Stability Light Intensity: 5%/y
Response Time Temperature: 18s (1m/s wind speed)
Response Time Humidity: 6s (1m/s wind speed)
Response Time Light Intensity: 0.1s
Basic Communication Parameters:
v:* {behavior:url(
default
VML);}
o:* {behavior:url(
default
VML);}
x:* {behavior:url(
default
VML);}
.shape {behavior:url(
default
VML);}
Coding
8 bits binarysystem
Data bits
8 bits
Parity check bit
None
Stop bit
1 bit
Error check
CRC(redundant cyclic code)
Baud rate can be set
2400bit/s,4800bit/s and 9600 bit/s can be set, and the factory default is 4800bit/s
Data Frame Format Definition:
Adopt Modbus-RTU communication protocol, the format is as follows:
Initial structure 4 bytes of time
Address code = 1 byte
Function code = 1 byte
Data area = N bytes
Error check = 16-bit CRC code
End structure 4 bytes of time
Address Code: is the address of the transmitter, which is unique in the communication network (factory default 0x01).
Function Code: The instruction function of the command sent by the host. This transmitter only uses function code 0x03 (read register data).
Data Area: The data area is the specific communication data. Note that the 16bits data high by
-
Fruugo ID:
182883622-390413566
-
EAN: